Fluke Networks DSX2-8000-ADD-R Remote

$8,913.00

Technical Specs

Fluke Networks DSX2-8000-ADD-R - DSX2-8000 Add-on Kit with Remote Specs

Brand Monarch
Shielded and unshielded pair LAN cabling TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA, and I/II: 100 Ω and 120 Ω
Permanent link adapters Plug type: shielded RJ45   Optional Plug type: Tera
Channel adapters Jack type: shielded RJ45   Optional Jack type: Tera, GG45
TIA Cat 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D
ISO/IEC Class C, D, E, EA, F, FA, I/II certification per ISO/IEC
Maximum frequency DSX-8000: 2000 MHz;   DSX-5000 1000 MHz
Speed of Autotest DSX-8000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Cat 6A/Class EA: 8 seconds. Full 2- way Autotest of Category 8: 16 seconds   DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near-End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT), Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL).
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing over mold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium-ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual-band (2.4 GHz and 5 GHz)
Operating Temperature 32° F to 113° F (0° C to 45° C)
Storage Temperature -14° F to +140° F (-10° C to +60° C)
Operating relative humidity (% RH without condensation) 0% to 90%, 32° F to 95° F (0° C to 35° C)   0% to 70%, 95° F to 113° F (35° C to 45 °C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude 13,123 ft (4,000 m)   10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1
DSX-8000 Category 8 test modes (or lower link categories) Class I/II test modes
DSX-5000 Category 6A/Class EA test modes (or lower link categories) Class FA test modes
Length of Twisted Pair Cabling Without Remote or in DSX-5000 Long Communication Mode
Range 800 m (2600 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m   ± (0.3 m + 4 %); 150 m to 800 m
Propagation Delay Without Remote or in DSX-5000 Long Communication Mode
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns   ± (2 ns + 4 %); 750 ns to 4000 ns
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.