Fluke Networks DSX2-8000MI 2 GHz DSX2-8000 Cable Analyzer

$15,306.00

Technical Specs

Fluke Networks DSX2-8000MI 2 GHz DSX2-8000 Cable Analyzer with Multimode OLTS, Fiber Inspection and Wi-Fi Specs

Brand Monarch
Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G
Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI
Without Remote With Remote
Range 800 m (2600 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m   ± (0.3 m + 4 %); 150 m to 800 m
Without Remote With Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns   ± (2 ns + 4 %); 750 ns to 4000 ns
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type InGaAs
Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2 < +/- 5% +/- 32 pW
Measurement Linearity3 < ± 0.1 dB
Re-calibration Period 1 year
Specification CertiFiber Pro Multimode Modules
Testing Speeds (excludes referencing times) Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)   Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)   Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2 Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested 50/125 µm or 62.5/125 µm
Source Type and Wavelengths LED source 850 nm ± 30 nm 1300 nm ± 20 nm
Maximum Length Measurement 12 km
Length Measurement Accuracy ± 1.5 m plus ± 1 % of length
Output Power (Nominal) ≥ -24 dBm with EF-TRC
Output Power Stability3 ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes
Source Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2 < +/- 5% +/- 32 pW
Measurement Linearity3 < ± 0.1 dB
Re-calibration Period 1 year
Title Requirement
Output Power >-5 dBm   <0 dBm   SMF-28 singlemode fiber   Continuous wave   SC/UPC connector
Operating Wavelength 650 nm nominal
Output Modes Continuous wave   Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm universal
Laser Safety Class II CDRH   Over operating temperature range
Title Requirement
Operating Temperature -18° C to 45° C
Storage Temperature -30° C to +60° C
Operating Relative Humidity   % RH without condensation 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)   0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapters
Safety CSA C22.2 No. 1010.1: 1992   EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree 2
Altitude Operating: 4,000 m; storage: 12,000 m
EMC EN 61326–1
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fluke Networks DSX2-8000MI 2 GHz DSX2-8000 Cable Analyzer”
SKU: Fluke-Networks-DSX2-8000MI Category: Brand: