Wohler A550 INDUSTRIAL – A 550 Industrial Combustion Analyzer (with O2/NO/COH/NO2/SO2)
$5,543.00
Technical Specs
Wohler A550 INDUSTRIAL - A 550 Industrial Combustion Analyzer (with O2/NO/COH/NO2/SO2) Specs
| Display | Volume % referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0.0 - 21.0 vol. % |
| Accuracy | ± 0.3 vol. % |
| Display | Volume ppm referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0 - 100,000 vol. ppm; resolution 1 vol. ppm |
| Accuracy | ± 100 vol. ppm (< 1,000 vol. ppm), otherwise 10 % of reading (with H2 < 5 % of reading) |
| Display | Volume ppm referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0 - 3,000 vol. ppm (continuously up to 1,000); |
| Accuracy | ±5 vol. ppm (<100 vol. ppm), otherwise 5 % of reading |
| Display | Volume ppm referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0 - 1,000 vol. ppm (continuously up to 200 vol. ppm); resolution 0.1 vol. ppm |
| Accuracy | ± 5 vol. ppm (< 100 ppm), otherwise 5 % of reading |
| Display | Volume ppm referenced to dry flue gas |
| Measurement principle | Electrochemical sensor |
| Range | 0 - 5,000 vol. ppm; resolution 0.1 vol. ppm (<1,000 vol. ppm), otherwise 1 vol. ppm |
| Accuracy | ± 10 vol. ppm (< 200 vol. ppm), otherwise 5 % of reading |
| Display | inWC |
| Measurement principle | Semi-conductor diaphragm |
| Range | 0.00 to ± 44.16 inWC; resolution 0.004 inWC |
| Accuracy | 0.008 inWC (< 0.16 inWC), otherwise 5 % of reading |
| Display | °F |
| Measurement principle | Thermocouple (NiCr-Ni) (NiCr-Ni) |
| Range | - 4 °F to 1,472 °F; resolution 32.18 °F |
| Accuracy | 32-271.4 °F: ± 35.6 °F 271.4-1,472 °F: ± 1.5 % of reading |
| Display | °F |
| Measurement principle | Thermocouple (NiCr-Ni) |
| Range | - 4 °F to 212 °F; resolution 32.2 °F |
| Accuracy | ±33.8 °F |
| Power supply | Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB |
| Battery operating time | Approx. 7 h (depends on operating status and display illumination) |
| Storage temperature | 4 °F to + 122 °F |
| Operating temperature | + 41 - 104 °F to maintain stated accuracy |
| Weight | 2.75 lbs |
| Dimensions | 8.7" x 6.3" x 2.2" (without probe) |
| Length of cable-hose | 67" |
Reviews (0)
Be the first to review “Wohler A550 INDUSTRIAL – A 550 Industrial Combustion Analyzer (with O2/NO/COH/NO2/SO2)” Cancel reply
You must be logged in to post a review.

Reviews