Fluke Networks MS2-FTK Copper/Fiber Basic Technicians Kit

$2,191.00

Technical Specs

Fluke Networks MS2-FTK Copper/Fiber Basic Technicians Kit (MS2-100 + FTK-1000) Specs

Test Connectors Twisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs   Coax: F-connector for 75 O, 50 O, 93 O cables
Cable Tests Length (460 m or 1500 ft. with resolution to 0.3 m or 1 ft.), wiremap to TIA-568A/B standards, remote ID locators; displays results on one screen
Tone Generator IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz]
PoE Detection Solicits and detects the presence of 802.3af compatible PoE (Power over Ethernet) devices
Ethernet Port Test Advertised speed of 802.3 Ethernet ports (10/100/1000)
Power Source Battery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries   Battery life: 20 hours of typical use   Other compatible battery types: 2 AA photo lithium, NIMH, NICAD
Dimensions 3 in x 6.4” x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm)
Weight 0.8 lbs. (363 grams)
Display Monochrome liquid crystal display (LCD) with backlight
Calibration User-configurable NVP for twisted pair and coax; determines actual NVP with known length of cable
Operating Temperature 32 °F to 113 °F (0 °C to 45 °C)
Storage Temperature -4 °F to +140 °F (-20 °C to +60 °C)
Operating Humidity 90 % (50 °F to 95 °F; 10 °C to 35 °C)
(%RH without condensing) 75 % (95 °F to 113 °F; 35 °C to 45 °C)
Shock Vibration Meets requirements for MIL-PRF-28800F for Class 2 random vibration   1 m drop test with and without wiremap adapter attached
Safety EN 61010-1 2nd Edition
Altitude 4000 m; Storage: 12000 m
EMC EN 61326-1
Agency Certifications N10140 C-Tick EMC standard; FCC Part 15 Class A; CE   European Union Directives Pollution Degree 2
Warranty One year
Temperature range Operating: -10º C to 50º C   Storage: -20º C to 50º C
Operating Humidity 95% (10º C to 35º C) Non-Condensing   75% (35º C to 40º C) Non-Condensing   Uncontrolled <10º C
EMI, RFI, EMC Standards compliant1
Notes 1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
Detector Type InGaAs
Calibrated Wavelengths 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
Emitter wavelengths 850/1300 Source: 850 nm and 1300 nm   1310 Source: 1310 nm   1550 Source: 1550 nm
Measurement Range +10 to -52 dBm (850 nm)   +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Linearity ±0.2 dB (850 nm)1   ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2
Power Measurement Uncertainty3 ±0.25 dB
Display Resolution, dB or dBm 0.01 dB
Auto Dual-Wavelength Switching Yes
Power Display Units dBm, mW, µW
Auto-Wavelength Detection Yes
Data Storage 1000 records, multiple wavelengths per record
External Interface USB, 2.0 full speed
Optical Connector Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate 1 reading per second
Reference Individually set for each wavelength
FindFiber ID detection Yes
Power Requirement 2 AA Alkaline batteries
Battery Life4 > 50 Hours (typical)
Automatic Power Off 10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning Yes, low battery icon blinks
Size (L x W x H) 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight 11.5 oz (325 grams)
Notes 1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power 0 dBm and < -55 dBm   3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm   4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Emitter Type LED
Central Wavelength 850 nm, 1300 nm
Wavelength Accuracy 850 nm: +30/- 10 nm   1300 nm: ± 20 nm
Spectral Width (FWHM) 850 nm: 50 nm (typical)   1300 nm: 135 nm (typical)
Minimum Output Power 850/1300 nm: ³ -20 dBm
Power Output Stability1 ±0.1 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled/disabled by user.
Optical Output Connector Fixed SC
FindFiber Code Generation Yes. Fixed at ID 1.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries.
Battery Life2 40 hrs (typical)
Automatic Power Off 30 minutes (can be disabled by user)
Low Battery Warning Yes, LED blinks
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 1.8 oz (278 g)
Notes 1 23° C ± 2° C, after 5 minutes warm-up time   2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fluke Networks MS2-FTK Copper/Fiber Basic Technicians Kit”
SKU: Fluke-Networks-MS2-FTK Category: Brand: