Technical Specs
Fluke Networks MS2-FTK Copper/Fiber Basic Technicians Kit (MS2-100 + FTK-1000) Specs
| Test Connectors | Twisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs Coax: F-connector for 75 O, 50 O, 93 O cables |
| Cable Tests | Length (460 m or 1500 ft. with resolution to 0.3 m or 1 ft.), wiremap to TIA-568A/B standards, remote ID locators; displays results on one screen |
| Tone Generator | IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz] |
| PoE Detection | Solicits and detects the presence of 802.3af compatible PoE (Power over Ethernet) devices |
| Ethernet Port Test | Advertised speed of 802.3 Ethernet ports (10/100/1000) |
| Power Source | Battery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries Battery life: 20 hours of typical use Other compatible battery types: 2 AA photo lithium, NIMH, NICAD |
| Dimensions | 3 in x 6.4” x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm) |
| Weight | 0.8 lbs. (363 grams) |
| Display | Monochrome liquid crystal display (LCD) with backlight |
| Calibration | User-configurable NVP for twisted pair and coax; determines actual NVP with known length of cable |
| Operating Temperature | 32 °F to 113 °F (0 °C to 45 °C) |
| Storage Temperature | -4 °F to +140 °F (-20 °C to +60 °C) |
| Operating Humidity | 90 % (50 °F to 95 °F; 10 °C to 35 °C) |
| (%RH without condensing) | 75 % (95 °F to 113 °F; 35 °C to 45 °C) |
| Shock Vibration | Meets requirements for MIL-PRF-28800F for Class 2 random vibration 1 m drop test with and without wiremap adapter attached |
| Safety | EN 61010-1 2nd Edition |
| Altitude | 4000 m; Storage: 12000 m |
| EMC | EN 61326-1 |
| Agency Certifications | N10140 C-Tick EMC standard; FCC Part 15 Class A; CE European Union Directives Pollution Degree 2 |
| Warranty | One year |
| Temperature range | Operating: -10º C to 50º C Storage: -20º C to 50º C |
| Operating Humidity | 95% (10º C to 35º C) Non-Condensing 75% (35º C to 40º C) Non-Condensing Uncontrolled <10º C |
| EMI, RFI, EMC | Standards compliant1 |
| Notes | 1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1) |
| Detector Type | InGaAs |
| Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
| Emitter wavelengths | 850/1300 Source: 850 nm and 1300 nm 1310 Source: 1310 nm 1550 Source: 1550 nm |
| Measurement Range | +10 to -52 dBm (850 nm) +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm) |
| Power Measurement Linearity | ±0.2 dB (850 nm)1 ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2 |
| Power Measurement Uncertainty3 | ±0.25 dB |
| Display Resolution, dB or dBm | 0.01 dB |
| Auto Dual-Wavelength Switching | Yes |
| Power Display Units | dBm, mW, µW |
| Auto-Wavelength Detection | Yes |
| Data Storage | 1000 records, multiple wavelengths per record |
| External Interface | USB, 2.0 full speed |
| Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST |
| Display update rate | 1 reading per second |
| Reference | Individually set for each wavelength |
| FindFiber ID detection | Yes |
| Power Requirement | 2 AA Alkaline batteries |
| Battery Life4 | > 50 Hours (typical) |
| Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) |
| Low Battery Warning | Yes, low battery icon blinks |
| Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) |
| Weight | 11.5 oz (325 grams) |
| Notes | 1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power 0 dBm and < -55 dBm 3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm 4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries. |
| Emitter Type | LED |
| Central Wavelength | 850 nm, 1300 nm |
| Wavelength Accuracy | 850 nm: +30/- 10 nm 1300 nm: ± 20 nm |
| Spectral Width (FWHM) | 850 nm: 50 nm (typical) 1300 nm: 135 nm (typical) |
| Minimum Output Power | 850/1300 nm: ³ -20 dBm |
| Power Output Stability1 | ±0.1 dB over 8 hours |
| Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. |
| Optical Output Connector | Fixed SC |
| FindFiber Code Generation | Yes. Fixed at ID 1. |
| Modes | CW, 2 kHz modulated, Auto-wavelength |
| Power Requirement | 2 AA Alkaline batteries. |
| Battery Life2 | 40 hrs (typical) |
| Automatic Power Off | 30 minutes (can be disabled by user) |
| Low Battery Warning | Yes, LED blinks |
| Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
| Weight | 1.8 oz (278 g) |
| Notes | 1 23° C ± 2° C, after 5 minutes warm-up time 2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries. |
Reviews (0)
Be the first to review “Fluke Networks MS2-FTK Copper/Fiber Basic Technicians Kit” Cancel reply
You must be logged in to post a review.

Reviews
There are no reviews yet.