TTi CPX400DP – Dual output 840 watt PowerFlex PSU with USB, RS232, LAN

$1,414.00

Technical Specs

TTi CPX400DP - Dual output 840 watt PowerFlex PSU with USB, RS232, LAN Specs

Voltage Range 0V to 60V.
Current Range 0A to 20A.
Power Range Up to 420W subject to power envelope.
Voltage Setting By coarse and fine controls
Current Setting By single logarithmic control
Output Mode Constant voltage or constant current with automatic cross-over.   CC indicator lit in constant current mode.
Output Switch Electronic, non isolating. Preset voltage and current limit displayed when Output is off. Output rise time no load <10ms.
View Settings With the output On, the meters show actual voltage and current. The preset levels can be viewed and adjusted at any time by pressing the View Settings button.
Status Indication LED indication of Output On, V/I Limits, CV, CI, Power Limit, Remote, LAN status. Message on meter display for trip condition.
Ripple & Noise Typically <3mV rms, <15mV pk-pk, (5mV rms max.) in CV mode.
Load Regulation Voltage - <0·01% of maximum output for any load change within the PowerFlex envelope (remote sense connected).   Current - <0·05% of maximum output for any load change within the PowerFlex envelope.
Line Regulation Voltage - <0·01% of maximum output for a 10% line change.   Current - <0·01% of maximum output for a 10% line change.
Transient Response <250µs to within 50mV of setting for a 5% to 95% load change.
Temp. Coefficient Typically <100ppm/°C
Output Protection Forward protection by Over-voltage Protection (OVP) trip.   Reverse protection by diode clamp for currents to 3A.
OVP Setting/Range Via screwdriver adjustable preset on front panel. Range 1V to 66V
Over-temperature Output trips off for over-temperature.
Safety Interlocks Operations that could cause an unexpected change in voltage or current settings are interlocked with the output switch.
Output Terminals Universal 4mm safety binding posts on 19mm (0·75”) spacing at front.   Screw terminals at rear (CPX400SA, SP & DP only).
Sense Selection Voltage sensing is selected as Local or Remote by front panel switch.
Sense Terminals Sprung loaded screw-less terminals at front.   Screw terminals at rear (CPX400SA, SP & DP only).
Display Type Dual 4-digit meters, 10mm (0·39”) LED.
Resolution/ Accuracy 10mV / ± 0·1% of reading ± 2 digits
Resolution/ Accuracy 10mA / ± 0·3% of reading ± 20mA
Track Accuracy Slave voltage = ± (0·1% of Master voltage setting + 10mV)
Input Scaling 0 to 100% control of voltage or current from 0 to 5V or 0 to 10V (selectable)
Input Accuracy Voltage: 0.3% ±20mV.   Current: 0.5% ±50mA.   Input impedance: 10kW
Output Scaling Set values of 0 to 100% of rated output voltage and current generate 0 to 5V (not isolated)
Output Accuracy Voltage: 0.3% ±20mV.   Current: 0.5% ±50mA.   Output impedance: 125W
Remote On/Off Output On/Off can be controlled by external switch closure (not isolated)
RS-232 Standard 9-pin D connector. Baud rate 9,600
USB USB 2.0 connection (backwards compatible with USB 1.x). Operates as a virtual COM port
Ethernet (LAN) Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol for connection to Local Area Network or direct connection to a single PC.
LXI Compliance LAN interface is compliant with LXI class C. (LXI is the abbreviation for Lan extensions for Instrumentation).
Resolution/Accuracy 1mV / ± (0.05% +10mV)
Resolution/Accuracy 1mA / ± (0.3% +5mA)
Command Delay Typically <25ms (this must be added to any of the figures below)
Voltage Up Time <10ms* to 1%
Voltage Down Time <80ms* to 1% (full load); <1.5s* to 1% (no load)
AC Input 110 to 240 volts ±10% 50/60Hz. Installation Category II.
Input Power Single - 625VA, Dual - 1250VA max.
Operating Range +5ºC to +40ºC, 20% to 80% RH
Storage Range -40ºC to + 70ºC
Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2
Cooling Rear discharge variable speed fan.
Safety Complies with EN61010-1
EMC Complies with EN61326
Size Single - 107 x 130 (¼ rack 3U) x 398mm   Dual - 210 x 130 mm (½ rack 3U) x 377mm   (size excludes feet, knobs and terminals).
Weight Single - 4.25kg (9.35lb), Dual - 6.3kg (13.9lb)
IVI Driver An IVI driver for Windows is supplied. This provides support for common applications such as LabView*, LabWindows*, HPVEE* etc.
USB Driver An installation file is supplied which calls a standard Windows* USB driver.