Technical Specs
Fieldpiece JL3KR4 - Job Link Probes Charge Kit Specs
| Minimum Device Requirement | BLE 4.0 devices running iOS® 7.0 or AndroidTM 5.0 (Latest compatibility at www.fieldpiece.com) |
| Sensor Type | Relative pressure |
| Connector Type | Standard 1/4" NPT female flare fitting (angled) |
| Measurement Range | 29" HgV to 580 psig, 74 cmHgV to 0 to 4000 kPa |
| Accuracy | 29" HgV to 0" HgV: ±0.2" HgV; 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 psig: ±1 psig; 0 to 1378 kPa: ±7 kPa 200 to 580 psig: ±2 psig; 1378 to 4000 kPa: ±14 kPa |
| Maximum Overload Pressure | 800 psig (5500 kPa) |
| Battery Type | 2 x AAA, NEDA 24A, IEC LR03 |
| Battery Life | 150 hours typical alkaline. LED blinks red when battery replacement is needed. |
| Auto Power Off | 2 hours (APO can be disabled) |
| Wireless Range | 350 feet (107 meters) line of sight. Obstructions affect distance. |
| Radio Frequency | 2.4 GHz |
| Operating Environment | 32°F to 122°F (0°C to 50°C) at <75% RH |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with batteries removed) |
| Temperature Coefficient | 0.1 x (specified accuracy) per 0.6°F (32°F to 64°F, 82°F to 122°F), per 1°C (0°C to 18°C, 28°C to 50°C) |
| Weight | 0.39 lbs (177 g) |
| Water Resistant | Designed to IP55 |
| Minimum Device Requirement | BLE 4.0 devices running iOS® 7.0 or AndroidTM 5.0 (Latest compatibility at www.fieldpiece.com) |
| Pipe Contact Surface Compatibility | Electrically conductive |
| Pipe Size Compatibility | 1/4" to 1 3/8" (6.4mm to 34.9mm) OD |
| Sensor Type | Rapid Rail™ thermocouple (nickel chromium / nickel aluminum) |
| Measurement Feedback | Beeper and LED |
| Measurement Range | -50°F to 257°F (-46°C to 125°C) Plastic body and wire insulation are designed to withstand a maximum continuous temperature of 257°F (125°C). |
| Stabilization Time | 3 seconds typical |
| Accuracy | ±1.0°F (±0.6°C)* *Meets California's Title 24 requirements |
| Battery Type | 2 x AAA, NEDA 24A, IEC LR03 |
| Battery Life | 150 hours typical alkaline. LED blinks red when battery replacement is needed. |
| Auto Power Off | 2 hours (APO can be disabled) |
| Wireless Range | 350 feet (107 meters) line of sight. Obstructions affect distance. |
| Radio Frequency | 2.4 GHz |
| Operating Environment | 32°F to 122°F (0°C to 50°C) at <75% RH |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with batteries removed) |
| Temperature Coefficient | 0.1 x (specified accuracy) per 0.6°F (32°F to 64°F, 82°F to 122°F), per 1°C (0°C to 18°C, 28°C to 50°C) |
| Weight | 0.33 lbs (150 g) |
| Water Resistant | Designed to IP55 |
| Patent | Pending |
Reviews (0)
Be the first to review “Fieldpiece JL3KR4 – Job Link Probes Charge Kit” Cancel reply
You must be logged in to post a review.

Reviews