Fluke 1738/EUS 3-Phase Portable Advanced Power Logger EU/U

$5,606.00

Technical Specs

Fluke 1738/EUS 3-Phase Portable Advanced Power Logger EU/US Version Specs

Parameter Range
Voltage 1000 V
Current i17xx-flex 1500 12”
i17xx-flex 3000 24 300 A   3000 A
i17xx-flex 6000 36” 600 A   6000 A
i40s-EL clamp 4 A   40 A
Frequency 42.5 Hz to 69 Hz
Aux input ± 10 V dc
Voltage min/max 1000 V
Current min/max defined by   accessory
THD on voltage 1000%
THD on current 1000%
Voltage harmonics 2nd ...50th 1000 V
Current harmonics 2nd ...   50th defined by   accessory
Unbalance 100%
Parameter Influence   quantity
Active Power PActive Energy Ea PF = 0.99
Apparent Power S Apparent Energy Eap 0 = PF = 1
Reactive Power Q Reactive Energy Er 0 = PF = 1
Power Factor PF Displacement Power FactorDPF/cosφ –
Additional uncertainty in % of range1 V P-N > 250 V
Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit
Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency ≥ 68.2 % (in accordance with energy efficiency regulations)
Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input
Mains power frequency 50/60 Hz ± 15 %
Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time < 6 hours
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency 50/60 Hz (42.5 to 69 Hz)
Circuit types 1-?, 1-? IT, split phase, 3-? delta, 3-? wye, 3-? wye IT, 3-? wye balanced, 3-?   Aron/Blondel (2-element delta), 3-? delta open leg, currents only (load studies)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events 1
Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental   power, DPF, energy
Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to   IEC61000-4-30   Aux, Power: 200ms
Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Measured parameter Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD   A, TDD
Averaging interval 10 min
Individual harmonics 2nd ...50th harmonic
Total harmonic distortion Calculated on 50 harmonics
Events Voltage: dips, swells, interruptions, current: inrush current
Triggered recordings Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according   to IEC61000-4-30)   Waveform of voltage and current
Harmonics IEC 61000-4-7: Class 1   IEEE 519 (short time harmonics)
Power quality IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)
Power IEEE 1459
Power quality compliance EN50160 (for measured parameters)
USB-A File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
WiFi File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect ® 3000 series modules   (requires 1738, or 1736 upgrade option)
USB-mini Data download device to PC
Number of inputs 4 (3 phases and neutral)
Maximum input voltage 1000 Vrms, CF 1.7
Input impedance 10 MΩ
Bandwidth 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Measurement category 1000 V CAT III/600 V CAT IV
Number of inputs 4, mode selected automatically for attached sensor
Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal   probe range
Range 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”
Bandwidth 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Number of inputs 2
Input range 0 to ± 10 V dc, 1 reading/s
Scale factor Format: mx + b (gain and offset) user configurable
Displayed units User configurable (7 characters, for example, °C, psi, or m/s)
Number of inputs 2
Supported modules Fluke Connect ® 3000 series
Acquisition 1 reading/s
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH   30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH   40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
Operating altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000 m
Enclosure IP50 in accordance with EN60529
Vibration MIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1       IEC Mains Input:Overvoltage Category II, Pollution Degree 2       Voltage Terminals:Overvoltage Category IV, Pollution Degree 2
Electromagnetic compatibility (EMC) EN 61326-1: Industrial CISPR 11: Group 1, Class A
Temperature coefficient 0.1 x accuracy specification/°C
Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty Instrument and power supply: Two-years (battery not included)   Accessories: one-year   Calibration cycle: two-years
Dimensions Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)   Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)   Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm   (7.8 in x 6.6 in x 3.5 in)
Weight Instrument: 1.1 kg (2.5 lb)   Power supply: 400 g (0.9 lb)
Tamper protection Kensington lock slot
Measuring range 1 to 150 A ac/10 to 1500 A ac
Nondestructive current 100 kA (50/60 Hz)
Intrinsic error at reference condition* ± 0.7 % of reading
Accuracy 173x + iFlex ± (1 % of reading + 0.02 % of range)
Temperature coefficient over operating temperature range 0.05 % of reading/°C 0.09 % of reading/°F
Working voltage 1000 V CAT III, 600 V CAT IV
Probe cable length 305 mm (12 in)
Probe cable diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Output cable length 2 m (6.6 ft)
Weight 115 g
Probe cable material TPR
Coupling material POM + ABS/PC
Output cable TPR/PVC
Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of   conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating 15 % to 85 % non-condensing
IP rating IEC 60529:IP50
Warranty One-year
1736 Power Logger 1738 Power Logger
FLUKE-1736/B FLUKE-1736/EUS
Model Power logger basic version
PQ Health (EN50160 analysis) Opt.
IEEE 519 reporting Opt.
Fluke Connect ® module support   (up to 2 modules**) Opt.
Trend •
Waveform Snapshots + RMS profile Opt.
USB (mini B) •
WiFi download of instrument data •
WiFi download via WiFi access point (requires registration)** Opt.
WiFi only adapter** -
WiFi and BLE adapter** Opt.
USB flash drive (4GB) •
USB Cable •
3PHVL-173 Flat Cable •
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fluke 1738/EUS 3-Phase Portable Advanced Power Logger EU/U”
SKU: Fluke-1738-EUS Category: Brand: