EEC 08540 – AC+DC Power Source, 4 kVA

$3,899.00

Technical Specs

EEC 08540 - AC+DC Power Source, 4 kVA Specs

INPUT 8540
Phase 1Ø2W
Voltage 200 - 240 V ± 10%
Max. Current 30A
Power Factor ≥0.97 at Full load
Power Rating 1Ø2W
Max. Current (r.m.s) 1Ø2W
0 - 310V 20A @ 200V
Inrush Current (peak) 1Ø2W
0 - 310V 80A
Frequency 5.0 - 1200 Hz
Phase 1Ø2W
THD (Total Harmonic Distortion) ≤0.3% @ 50/60Hz (Full Resistive Load)   ≤1.1% @ 5 -1000Hz (Full Resistive Load)   ≤1.2% @1001-1200Hz (Full Resistive Load)
Crest Factor ≥3
Line Regulation ±0.1V
Load Regulation (Hardware) ± (1% of output +0.5V) @ Resistive Load   < 400µS response time
Load Regulation (Software) ±0.2V, <1S response time
DC Offset ≤±30mV (typical)
Power Rating 2400W
Max. Current 0 - 210V
0 - 420V 24.0A
Ripple & Noise (rms) Range
H < 800mV
Ripple & Noise (p-p) < 7.0Vp-p
Voltage (AC) Range
Resolution 0.1V
Accuracy ±(0.2% of setting + 6 counts)
Voltage (DC) Range
Resolution 0.1V
Accuracy ±(0.2% of setting + 6counts)
Frequency Range
Resolution 0.1Hz at 0.0 - 999.9Hz, 1Hz at 1000 - 1200Hz
Accuracy ±0.03% of setting (≥15Hz)   ±0.3% of setting (<15Hz)
Start Angle Range
Resolution 1o
Current Hi Limit   (OC Fold=OFF)   OC Fold Back   (OC Fold = ON) 0 - 155V
0 - 310V 0.10 - 20.00A
Resolution 0.01 A
Accuracy ± (2.0% of setting + 4 counts)
OC Fold Back Response Time < 1.4S
Time Range
Resolution 0.1h   0.1Min   0.1s   0.1ms
Accuracy ± (0.1% + 0.1 Hour)   ± (0.1% + 0.1 Minute)   ± (0.1% + 0.1 sec)   ± (0.1% + 0.1 ms)
Time Unit Hour, Minute, Second, ms
Ramp Up Range
Resolution 0.1s
Accuracy ± (0.1% + 1 Cycle) at Output frequency ≤ 10Hz   ± (0.1% + 0.1 sec) at Output frequency > 10Hz
Frequency Range
Resolution 0.1Hz / 1Hz
Accuracy ±0.1Hz @ 5 - 999.9Hz., ±1Hz @ 1000 - 1200Hz
Voltage (AC) Range
Resolution 0.1V
Accuracy ±(0.2% of reading + 6 counts) at voltage > 5V
Voltage (DC) Range
Resolution 0.1V
Accuracy ±(0.2% of reading + 6 counts) at voltage > 5V
Current (AC, DC) Range
Resolution L
H 0.01A
Accuracy L
H ± (0.5% of reading +12 counts)
Current (AC, DC) Range
H 0 - 5000W
Resolution L
H 1W
Accuracy L
H ± (1% of reading +20 counts) at PF ≥ 0.3 and voltage > 5V
Power Factor Range
Resolution 0.001
Accuracy W/VA, Calculated and displayed to three significant digits
Power Apparent (VA) Range
H 0 - 5000VA
Resolution L
H 1VA
Calculated Formula V×A, Calculated value
Peak Current Measurement Range
Resolution 0.1A
Accuracy ± (0.5% of reading + 12 counts)
Reactive Power Measurement Range
H 0 - 5000VAR
Resolution L
H 0.01A
Calculated Formula (VA) 2 - (W) 2
Crest Factor Measurement Range
Resolution 0.01
Calculated Formula Ap / A
Software OCP ≤110% of full rated current (102% 5 second output shut down   >110% of full rated current, <1.5 second output shut down
Output Short Shut Down Speed <1 second
Software OPP ≤110% of full rated current (102% 5 second output shut down, >110% of full rated current, <1.5 second output shut down
Software OVP Over voltage 105% of full rated voltage
Software VSENSE OVP H
L When measurement voltage exceeds setting voltage 5V
Software VSENSE LVP H
L When measurement voltage is lower than setting voltage 5V
Hardware OTP Temperature over 108oC on power component of the PFC and DDC   Temperature over 100oC on heatsink of the power amplifier
Software RCP (Reverse Current Protection) When reverse power over 5% of full rated power
Hardware FAN FAIL When fan fails and fan is blocked
Dimension by Model (mm) W
H 176
D 500
Weight 28KG
Storage Environment -40° to 75°C
Operation Environment 0-40oC/20-85% RH
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “EEC 08540 – AC+DC Power Source, 4 kVA”
SKU: EEC-08540 Category: Brand: