Rigol DSG830 RF Signal Generator, 9 kHz to 3 GHz Specs

DSG815 DSG830
Frequency range 9 kHz to 1.5 GHz
Frequency resolution 0.01 Hz
Setting time[1] < 10 ms (typ.)
Band Frequency range
1 f < 227.5 MHz
2 227.5 MHz ≤ f < 455 MHz
3 455 MHz ≤ f < 910 MHz
4 910 MHz ≤ f < 1820 MHz
5 1820 MHz ≤ f ≤ 3000 MHz
Reference frequency 10 MHz
Temperature stability In temperature range 0℃ to 50℃ , reference to 25℃
With option OCXO-B08 < 5 ppb
Aging rate < 1 ppm/year
With option OCXO-B08 < 30 ppb/year
Internal reference frequency output Frequency
Level +5 dBm to +10 dBm
External reference frequency input Frequency
Level 0 dBm to +10 dBm
Maximum deviation ±5 ppm
Sweep type Step sweep (equally or logarithmically spaced frequency steps)   List sweep (list with arbitrary frequency steps)
Sweep mode Single, continuous
Sweep range Full frequency range
Sweep shape Triangle, ramp
Step change Linear or logarithmic
Number of points Step sweep
List sweep 1 to 6001
Dwell time 20 ms to 100 s
Trigger mode Auto, key, external, bus (USB, LAN)
DSG815 DSG830
Harmonic CW mode, 1 MHz ≤ f ≤ 3 GHz, level ≤ +13 dBm
Non-harmonic CW mode, level > -10 dBm, carrier offset > 10 kHz
100 kHz ≤ f ≤ 1.5 GHz < -60 dBc, < -70 dBc (typ.)
1.5 GHz < f ≤ 3 GHz < -54 dBc, < -64 dBc (typ.)
SSB phase noise CW mode, carrier offset = 20 kHz, 1 Hz measurement bandwidth
100 kHz ≤ f ≤ 1.5 GHz < -100 dBc/Hz, < -105 dBc/Hz (typ.)
1.5 GHz < f ≤ 3 GHz < -94 dBc/Hz, < -99 dBc/Hz (typ.)
Residual FM CW mode, RMS value at f = 1 GHz
0.3 kHz to 3 kHz < 10 Hz rms, < 5 Hz rms (typ.)
0.03 kHz to 20 kHz < 50 Hz rms, < 10 Hz rms (typ.)
Specification level range Setting range
Maximum output level[1] 9 kHz ≤ f < 100 kHz
100 kHz ≤ f ≤ 3 GHz +13 dBm
Minimum output level 9 kHz ≤ f ≤ 100 kHz
100 kHz < f ≤ 3 GHz -110 dBm
Setting Resolution 0.01 dB
Level uncertainty Temperature range: 20℃ to 30℃
+13 dBm to -60 dBm -60 dBm to -110 dBm
100 kHz ≤ f ≤ 3 GHz ≤ 0.9 dB, ≤ 0.5 (typ.)
VSWR[2] 1 MHz ≤ f ≤ 3 GHz
Setting time[3] Fixed frequency, temperature range: 20℃ to 30℃
Max. reverse power Max. DC voltage
1 MHz < f ≤ 3 GHz 1 W
Sweep type Step sweep (equally spaced level steps)   List sweep (list with arbitrary level steps)
Sweep mode Single, continuous
Sweep range Full level range
Sweep shape Triangle, ramp
Step change Linear
Number of points Step sweep
List sweep 1 to 6001
Dwell time 20 ms to 100 s
Trigger mode Auto, key, external, bus (USB, LAN)
Waveform Sine, square
Frequency range Sine
Square DC to 20 kHz
Resolution 0.01 Hz
Frequency error The same with that of the RF reference source
Voltage range AC
DC -3 V to 3 V
Voltage resolution 2 mV
AM FM
AM -
FM ○
ØM ○
Pulse mod. (opt.) △
Modulation source Internal, external
Modulation depth[2] 0% to 100%
Resolution 0.1%
Setting uncertainty fmod = 1 kHz
Distortion fmod = 1 kHz, m < 30%, level = 0 dBm
Modulation frequency response m < 80%, DC/10 Hz to 100 kHz
Modulation source Internal, external
Max. deviation N × 1 MHz (nom.)
Resolution < 0.1% of the deviation or 0.01 rad, take the greater one (nom.)
Setting uncertainty fmod = 1 kHz, internal modulation
Distortion fmod = 1 kHz, deviation = N × 50 kHz
Modulation frequency response[3] DC/10 Hz to 100 kHz
Modulation source Internal, external
Max. deviation N × 5 rad (nom.)
Resolution < 0.1% of the deviation or 0.01 rad, take the greater one (nom.)
Setting uncertainty fmod = 1 kHz, internal modulation
Distortion fmod = 1 kHz, deviation = N × 5 rad
Modulation frequency response[4] DC/10 Hz to 100 kHz
Modulation source External, internal
On/off ratio 100 kHz ≤ f < 3 GHz
Rise/fall time (10%/90%) < 50 ns, 10 ns (typ.)
Pulse repetition frequency DC to 1 MHz
Pulse mode Single pulse, pulse train (option DSG800-PUG)
Pulse period Setting range
Resolution 10 ns
Pulse width Setting range
Resolution 10 ns
Trigger delay Setting range
Resolution 10 ns
Trigger mode Auto, external trigger, external gate, key, bus (USB, LAN)
Pulse train generator Number of pulse patterns
On/off time range 20 ns to 170 s
Number of repetitions per pattern 1 to 256
RF output Impedance
Connector N female
Internal modulation generator (LF) output Impedance
Connector BNC female
External trigger input Impedance
Connector BNC female
Trigger voltage 3.3 V TTL level
Signal valid output Connector
Output voltage 0 V/3.3 V (nom.)
Pulse input or output Impedance
Input/output voltage 0 V/3.3 V (nom.)
External modulating signal input Impedance
Coupling Coupling
Sensitivity 1 V peak-peak for indicated modulation depth or deviation (nom.)
Connector BNC female
10MHz input (external frequency reference input) Impedance
Connector BNC female
10MHz output (external frequency reference output) Impedance
Connector BNC female
USB host Connector
Protocol Version 2.0
USB device Connector
Protocol Version 2.0
LAN LXI Core 2011 Device
Type TFT LCD
Resolution 320 (RGB) × 240
Size 3.5 inches
Mass storage Flash non-volatile memory (internal); USB storage device (not supplied)
Data storage space Flash non-volatile memory (internal)
Input voltage range, AC 100 V to 240 V (nom.)
AC frequency range 45 Hz to 440 Hz
Power consumption With all the options
Certificate of conformity CE
EMC Conform to EMC instruction (2014/30/EU), Conform to or exceed IEC61326-1: 2013/EN61326-1: 2013 Group 1 Class A standard
IEC 61000-4-2:2008/EN 61000-4-2 ±4.0 kV (contact discharge), ±8.0 kV (air discharge)
IEC 61000-4-3:2002/EN 61000-4-3 3 V/m (80 MHz to 1 GHz)   3 V/m (1.4 GHz to 2 GHz)   1 V/m (2.0 GHz to 2.7 GHz)
IEC 61000-4-4:2004/EN 61000-4-4 1 kV power cable
IEC 61000-4-5:2001/EN 61000-4-5 0.5 kV (Phase to Neutral)   1 kV (Phase to PE)   1 kV (Neutral to PE)
IEC 61000-4-6:2003/EN 61000-4-6 3 V, 0.15 MHz to 80 MHz
IEC 61000-4-8:2009 3 A/m (50 Hz, 60 Hz)
IEC 61000-4-11:2004/EN 61000-4-11 Voltage dip:   0% UT during half cycle   0% UT during 1 cycle   70% UT during 25 cycles   Short interruption:   0% UT during 250 cycles
Safety regulation Conform to:   IEC 61010-1:2010 (Third Edition)/EN 61010-1:2010,   UL 61010-1:2012 R4.16 and CAN/CSA-C22.2 NO. 61010-1-12+ GI1+ GI2
Temperature Operating temperature range
Storage temperature range -20℃ to 70℃
Humidity 0℃ to 30℃
30℃ to 40℃ ≤ 75% rel. humidity
40℃ to 50℃ ≤ 45% rel. humidity
Altitude Operating height
(W × H × D) 261.5 mm × 112 mm × 318.4 mm   (10.30 inch × 4.41 inch × 12.54 inch)
Recommended calibration interval 18 months