Hioki IM3536 LCR Meter, DC 4Hz-8MHz, 1ms, 6 Digits

$3,371.00

Technical Specs

Hioki IM3536 - LCR Meter, DC 4Hz-8MHz, 1ms, 6 Digits, Exit I/O/USB/LAN/GP-IB/RS-232C, IM3500 Series Specs

Measurement modes LCR mode, Continuous measurement mode
Measurement parameters Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
Measurement range 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display range Z: 0.00 m to 9.99999 GΩ, Rs, Rp, Rdc, X: ±(0.00 m to 9.99999 GΩ)   G, B: ±(0.000 n to 9.99999 GS), Ls, Lp: ±(0.00000 μ to 9.99999 GH),   Cs, Cp: ±(0.0000 p to 9.99999 GF), Y: 0.000 n to 9.99999 GS,   θ : ±(0.000° to 999.999°), Q: ±(0.00 to 9999.99),   D : ±(0.00000 to 9.99999), Δ % : ±(0.000 % to 999.999%)
Basic accuracy Z ±0.05% rdg. θ: ±0.03° (represestative value, Measurable range: 1 mΩ to 200 MΩ)
Measurement frequency 4 Hz to 8 MHz (10 mHz to 100 Hz steps)
Measurement signal level [Normal mode: V mode/CV mode]   4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA)   1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA)   [Low impedance high accuracy mode: V mode/CV mode]   4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA)   [Normal mode: CC mode]   4 Hz to 1.0000 MHz: 10 μA to 50 mA (maximum 5 V)   1.0001 MHz to 8 MHz: 10 μA to 10 mA (maximum 1 V)   [Low impedance high accuracy mode: CC mode]   4 Hz to 1.0000 MHz: 10 μA to 100 mA (maximum 1 V)   DC resistance measurement]   Measurement signal level: Fixed at 1 V
DC bias measurement Generating range: DC voltage 0 V to 2.50 V (10mV resolution)   In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
Display 5.7-inch color TFT with touch panel
Functions Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger   function, Open/short compensation, Contact check, Panel loading/saving, Memory   function
Interfaces EXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Power supply 100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 230 mm (9.06 in) D, 4.2 kg (148.1 oz)
Accessories Power cord ×1, Instruction manual ×1, LCR application disc (Communications user   manual) ×1
Input type Optocoupler-isolated, non-voltage contact inputs (current sink, active-low)
Input asserted (on) voltage 0.9 V or less
Input de-asserted (off) voltage OPEN or 5 V to 24 V
Input asserted (on) current 3 mA/ch
Maximum applied voltage 30 V
Output type Isolated NPN open-collector outputs (current sink, active-low)
Maximum load voltage 30V
Maximum output current 50 mA/ch
Residual voltage 1 V (10 mA), 1.5 V (50 mA)
Output voltage 4.5 V to 5.0 V
Maximum output current 100 mA
External power input none
Measurement   parameters Z Impedance   Y Admittance   θ Phase angle   X Reactance   G Conductance   B Susceptance   Q Q-factor   Rdc DC resistance   Rs Equivalent series resistance (ESR)   Rp Equivalent parallel resistance   Ls Equivalent series inductance   Lp Equivalent parallel inductance   Cs Equivalent series capacitance   Cp Equivalent parallel capacitance   D Loss factor tan δ   σ Conductivity   ε Permittivity
Display range Z 0.00 m to 9.99999 GΩ   Y 0.000 n to 9.99999 GS   θ ±(0.000° to 999.999°)   X ±(0.00 m to 9.99999 GΩ)   G ±(0.000 n to 9.99999 GS)   B ±(0.000 n to 9.99999 GS)   Q ±(0.00 to 9999.99)   Rdc ±(0.00 m to 9.99999 GΩ   Rs ±(0.00 m to 9.99999 GΩ)   Rp ±(0.00 m to 9.99999 GΩ)   Ls ±(0.00000 μ to 9.99999 GH)   Lp ±(0.00000 μ to 9.99999 GH)   Cs ±(0.0000 p to 9.99999 GF)   Cp ±(0.0000 p to 9.99999 GF)   D ±(0.00000 to 9.99999)   Δ% ±(0.000% to 999.999%)   σ ±(0.00000 to 999.999 G)   ε ±(0.00000 to 999.999 G)
Measurable range 1 mΩ to 200 MΩ
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 10Ω
Range 4 Hz to 8 MHz
Resolution 4.00 Hz to 999.99 Hz …………… 10 mHz steps   .0000 kHz to 9.9999 kHz …… 100 mHz steps   10.000 kHz to 99.999 kHz …… 1 Hz steps   100.00 kHz to 999.99 kHz …… 10 Hz steps   1.0000 MHz to 8.0000 MHz …… 100 Hz steps
Accuracy ±0.01% of setting or less
Range [Normal mode]   4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA)   1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA)   [Low impedance high accuracy mode]   4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA)
Resolution 10 mV to 1.000 V …… 1 mV steps
Range [Normal mode]   4 Hz to 1.0000 MHz: 10 μA to 50 mA (maximum 5 V)   1.0001 MHz to 8 MHz: 10 μA to 1 mA (maximum 1 V)   [Low impedance high accuracy mode]   4 Hz to 1.0000 MHz: 10 μA to 100 mA (maximum 1 V)
Resolution 10 μA steps
Monitor function Monitor voltage range: 0.000 V to 5.000 V   Monitor current range: 0.000 mA to 100.0 mA
DC resistance   measurement Measurement signal level: Fixed at 1 V
DC bias measurement Generating range: DC voltage 0 V to 2.50 V (10mV resolution)   In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)
Measurement modes LCR mode: Measurement using a single set of conditions.   Continuous measurement mode: Continuous measurement   using previously saved conditions
Measurements Bin measurement: 10 categories for 2 measurement parameters   Judgment method: Set as absolute values, percentage, or   deviation percentage
Display Zoom display function: Enlarged display of measured values   Number of display digits setting: Allows you to set the number   of display digits for measured values for each measurement   parameter. (Valid setting range: 3 to 6 digits)
Measurements Performs continuous measurement using measurement condi-   tions that have been saved using the panel save function.   Measurement is started by an external trigger (any of the three   types described below)
Maximum number   of measurements 60
Measurement speed FAST/MED/SLOW/SLOW2
Averaging Valid setting range: 1 to 256 (in steps of 1)
Basic accuracy Z: 0.05% rdg. θ: 0.03° (representative value)
Guaranteed   accuracy range 1 mΩ to 200 MΩ (impedance)
Guaranteed   accuracy period 1 year
Warm-up time 60 minutes
Terminal structure 4-terminal structure
Trigger function Uses a specific signal to time the start of measurement.   [Trigger types]   Internal trigger: Automatically generates a trigger signal   internally to repeat measurement.   External trigger: Allows you to control the instrument   ,   s   measurement operation by inputting a trigger signal from   an external device (trigger sources: manual, communica-   tions commands, EXT. I/O).   [Trigger delay]   Sets the delay time from trigger input to measurement.   Setting range: 0.0000 s to 9.9999 s   [Trigger synchronous output]   Outputs the measurement signal after trigger input and ap-   plies it to the sample during measurement only.   Allows you to set a wait time until data is acquired.   Setting range: 0.0000 s to 9.9999 s
Compensation   function [Open/short compensation]   [Load compensation] Number of sets of compensation condi-   tions: Up to 5   [Cable length compensation] Cable length settings: 0 m, 1 m,   2 m, 4 m   [Correlation compensation] Compensation of display   values based on user-input compensation coefficient
Contact check [4-terminal contact check]   Performs a contact (disconnection) check between H CUR and   H POT and between L CUR and L POT.   [High-Z reject function]   Detection of OPEN state during 2-terminal measurement.
Memory function Measurement result items (maximum 32000 items) can   be saved to the instrument.   Memory can be read using communications commands   or a USB flash drive.
Panel save and load   functions Measurement conditions: Up to 60   Compensation values: Up to 128
Interfaces EXT. I/O( HANDLER) ,USB, USB flash drive, LAN,   GP-IB, RS-232C
BCD output [Output from EXT. I/O connector]   Generates BCD output for the No.1 and No.3 parameter   measured values.   *Input and output signals are set to BCD mode (selection   with judgment output).
Key lock function Lock operation of the instrument using the touch screen.   Unlock by entering a passcode.
Display settings LCD display on/off   Off: The display turns off 10 sec. after the touch panel is   last touched.
Display 5.7-inch color TFT with touch panel
Beep tone Enable or disable for judgment results and key operation.
Operating   temperature and   humidity 0°C to 40°C (32°F to 104°F), 80% RH, non-condensing
Storage   temperature and   humidity -10°C to 50°C (14°F to 122°F), 80% RH, non-condensing
Operating   environment Indoors, Pollution Degree 2, altitude up to 2000 m (6562-ft.)
Power supply and   maximum rated   power 100 V AC to 240 V AC (50/60 Hz), 50 VA
Dielectric strength 1.62 kV AC for 1 min. between power line and ground line
Standards compliance EMC: EN 61326, EN 61000   Safety: EN 61010
Dimensions and Mass Approx. 330 W × 119 H × 230 D mm (12.99 W × 4.69   H × 9.06 D in) , approx. 4.2 kg (148.1 oz.)
Accessories Power cord ×1, Instruction manual ×1,   LCR application disc (Communications user manual) ×1